Posted by
junwei on Friday, October 16, 2009 2:44:34 AM
Oilless
air compressor is an open-type cooling system, cooling
system mainly consists of all levels of cylinder, cylinder head, cylinder block,
one, two, three coolers, valves and pipes connected with the above components
composed of road.
Each distribution of cooling water volume can be adjusted
through the valve, adjust the amount of the size of the compressor at all
levels, in accordance with intake and exhaust temperatures to determine, through
the water regulating valve cylinder and the cooler water can be controlled, thus
ensuring export of the cooling water temperature. That would avoid the cylinder
when the machine idle excessive cooling, but also saves the cooling water.
Functions of dental
air compressors
1, Motor Protection
With the main circuit short-circuit, motor
missing phase, motor overload protection function.
2, automatic shutdown
protection function
When the oil pressure is too low, water pressure is
too low, discharge pressure is too high, motor (short circuit, overload, lack of
phase) has a protective function of automatic shutdown and fault indicators, and
sound and light alarm.
3, with cumulative work time-keeping.
4,
with the scene and start counter 2 start, stop and on-site emergency shutdown
feature.